inquiry
laisser un message
Si vous êtes intéressé par nos produits et souhaitez en savoir plus, veuillez laisser un message ici, nous vous répondrons dès que possible.
SOUMETTRE
Bengbu Longkai Welding Protection Technology Co., Ltd.
MAISON

PAPR pour le soudage et le meulage

PAPR pour le soudage et le meulage

  • Demolition Work: Choosing the Right PAPR
    Demolition Work: Choosing the Right PAPR
    Jan 20, 2026
      Demolition work involves complex and variable environments. From breaking down walls of old buildings to dismantling industrial facilities, pollutants such as dust, harmful gases, and volatile organic compounds (VOCs) are pervasive, placing extremely high demands on respiratory protection for workers. battery powered respirator have become core protective equipment in demolition work due to their advantages of positive pressure protection and low breathing load. However, not all PAPRs are suitable for all scenarios; selecting the right type is essential to build a solid line of defense for respiratory safety. Compared with traditional negative-pressure respirators, PAPRs actively deliver air through an electric fan, which not only reduces breathing fatigue during high-intensity operations but also prevents pollutant leakage through the positive pressure environment inside the mask, significantly improving protection reliability.   For general dust-generating demolition operations, particulate-filtering PAPRs are preferred. Such operations commonly involve the demolition of concrete, masonry, wood, and other components, with respirable dust—especially PM2.5 fine particles—as the primary pollutant. Long-term inhalation can easily induce pneumoconiosis. When selecting a model, high-efficiency particulate filters should be used, and the mask can be chosen based on operational flexibility needs. For open-air scenarios such as ordinary wall breaking and floor demolition, air-fed hood-type PAPRs are more suitable. They do not require a facial fit test, offer strong adaptability, and can also provide head impact protection. For narrow workspaces with extremely high dust concentrations, it is recommended to use tight-fitting full-face PAPRs, which have a minimum air flow rate of no less than 95L/min, forming a tight seal on the face to prevent dust from seeping through gaps.   For demolition operations involving harmful gases, combined-filtering PAPRs are required. During the demolition of old buildings, volatile organic compounds such as formaldehyde and benzene are emitted from paints and coatings, while the dismantling of industrial facilities may leave toxic gases such as ammonia and chlorine. In such cases, a single particulate-filtering PAPR cannot meet protection needs. Dual-filter elements (particulate + gas/vapor) should be used, with precise selection based on pollutant types: activated carbon filter cartridges for organic vapors, and chemical adsorption filter elements for acid gases. For these scenarios, positive-pressure tight-fitting PAPRs are preferred. Combined with forced air supply, they not only effectively filter harmful gases but also reduce pollutant residue inside the mask through continuous air supply, while avoiding poisoning risks caused by mask leakage.   Special scenarios require targeted selection of dedicated loose fitting powered air purifying respirators. Demolishing asbestos-containing components is a high-risk operation—once inhaled, asbestos fibers cause irreversible lung damage. PAPRs complying with asbestos protection standards should be used, paired with high-efficiency HEPA filters. Additionally, hood-type designs must be adopted to avoid fiber leakage due to improper wearing of tight-fitting masks. Meanwhile, the hood should be used with chemical protective clothing to form full-body protection. For demolition in confined spaces such as basements and pipe shafts, oxygen levels must first be tested. If the oxygen concentration is not less than 19% (non-IDLH environment), portable positive-pressure PAPRs can be used with forced ventilation systems. If there is a risk of oxygen deficiency, supplied-air respirators must be used instead of relying on PAPRs.   PAPR selection must balance compliance with standards and operational practicality.  Adjustments should also be made based on labor intensity: most demolition work is moderate to high intensity, so Powered Air Purifying Respirator TH3 are more effective in reducing breathing load, preventing workers from removing protective equipment due to fatigue. Battery life must match operation duration—for long-term outdoor operations, replaceable battery models are recommended to ensure uninterrupted protection. Furthermore, filter elements must be replaced strictly on schedule: gas filter cartridges should be replaced within 6 months of opening, or immediately if odors occur or resistance increases, to avoid protection failure.   Finally, it should be noted that PAPRs are not universal protective equipment, and their use must be based on a comprehensive risk assessment. Before demolition work, on-site testing should be conducted to identify pollutant types, concentrations, and environmental characteristics, followed by selecting the appropriate PAPR type for the scenario.  Only by selecting and using PAPRs correctly can we build a reliable barrier for respiratory health in complex demolition work, balancing operational efficiency and safety protection.If you want know more, please click www.newairsafety.com.
    EN SAVOIR PLUS
  • Protection de soudage avancée : soudage MAG et maintenance des appareils de protection respiratoire à ventilation assistée
    Protection de soudage avancée : soudage MAG et maintenance des appareils de protection respiratoire à ventilation assistée
    Oct 15, 2025
    Dans la première partie, nous avons abordé l'appariement TIG/MIG-PAPR. Abordons maintenant le soudage MAG (soudage sous gaz actif métal), un procédé intensif pour les ponts en acier ou les engins de chantier. Il utilise des mélanges argon-CO₂, générant 3 à 5 fois plus de fumées que le TIG, ainsi que du CO et des oxydes d'azote toxiques. Nous partagerons également des informations universelles. PAPR des règles pour assurer la fiabilité de votre protection.Soudage MAG : « Les risques importants » nécessitent des « respirateurs à ventilation assistée (PAPR) très résistants »Les triples menaces du MAG (fumées élevées, gaz toxiques, environnements difficiles) exigent des PAPR avec : Filtres combinés:HEPA pour la poussière + charbon actif pour CO/NOₓ (critique pour les magasins fermés) ;Masques à capuche:Couvrez les épaules pour bloquer les fumées soufflées par le vent (essentiel pour les travaux extérieurs comme les travaux sur les ponts) ;Conception robuste:Ventilateurs résistants aux vibrations (les soudures MAG vibrent fortement) et batteries interchangeables (pour des quarts de travail extérieurs de 8 heures sans électricité).Sélection d'un respirateur PAPR universel : 3 étapes simplesNe choisissez pas en fonction de la marque ou du prix, suivez ceci : Type de danger: TIG (gaz + poussière légère) → filtres de base ; MIG (poussière lourde + projections) → débit d'air élevé/résistant aux projections ; MAG (poussière + toxines) → filtres combinés + cagoules.Durée du quart de travail: ≤ 2 heures → PAPR légers ; ≥ 4 heures → filtres/débit d'air haute capacité.Environnement: Stations fixes intérieures → PAPR fixes ; extérieures/mobiles → modèles portables alimentés par batterie.Maintenance du PAPR : ne laissez pas votre équipement tomber en panne silencieusementSystème Papr perdre leur efficacité s'ils sont négligés — voici ce qu'il faut faire : Remplacer les filtres: TIG (1 à 2 semaines), MIG (3 à 5 jours), MAG (tous les jours s'il est sale) ; remplacez les filtres à charbon tous les mois ou si vous sentez des fumées.Vérifier le flux d'air: Effectuer un test hebdomadaire : TIG/MIG nécessite ≥ 150 L/min, MAG ≥ 180 L/min. Nettoyer les entrées d'air du ventilateur avec de l'air comprimé si le débit est bas.Entretien des masques: Essuyez la buée/l'huile après utilisation ; remplacez les films antibuée lorsqu'ils sont rayés (la buée bloque la vision et la sécurité). Du TIG au MAG, les PAPR sont plus efficaces lorsqu'ils sont adaptés aux dangers et bien entretenus. Pour les soudeurs, respirateur à air motorisé ce n'est pas seulement un équipement, c'est votre première ligne de défense pour une santé à long terme. Si vous voulez en savoir plus, vous pouvez cliquer www.newairsafety.com.
    EN SAVOIR PLUS

laisser un message

laisser un message
Si vous êtes intéressé par nos produits et souhaitez en savoir plus, veuillez laisser un message ici, nous vous répondrons dès que possible.
SOUMETTRE
CONTACTEZ-NOUS: sales@txhyfh.com

MAISON

PRODUITS

WhatsApp

Contactez-nous